missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Cytiva HiScreen™ MabSelect™, Xtra™, SuRe™, SuRe LX™ Prepacked Columns
Designed for method optimization and parameter screening for capture of monoclonal antibodies. Cytiva HiScreen™ MabSelect™, Xtra™, SuRe™, SuRe LX™ Prepacked Columns come ready-to-use for convenience.
Brand: Cytiva 17-5474-15
This item is not returnable.
View return policy
Description
- Ready-to-use columns for convenient process development
- Rigid, highly cross-linked agarose matrix
- Bed height of 10cm is designed to allow method optimization and parameter screening
- Easily connected in series to achieve 20cm bed height
- Small bed volume (4.7mL) gives fast result and minimal sample/buffer consumption
- Reproducible results, scalable to BioProcess columns packed with the same chromatography media using the same linear fluid velocity
MabSelect
- For capture of MAbs from large sample volumes
- Prepacked with protein A-derived media
- Compatible with high flow rates and high pressure when scaling up
- Increased binding capacity enables purification of MAbs from high-level expression feedstock
- Also optimized for Fc-fusion proteins
- Very low, unspecific binding due to high ligand selectivity and matrix hydrophilicity
- Prepacked with protein A-derived media
- With novel, alkali-tolerant recombinant protein A ligand that provides greater stability and allows use of 0.1 to 0.5M sodium hydroxide for cleaning-in-place (CIP)
- Enhanced protease resistance resulting in lower ligand leakage
- High dynamic binding capacity
Spécification
8M Urea, 6M Guanidine Hydrochloride, 2% Benzyl Alcohol or 20% Ethanol | |
Stoppers at the inlet and outlet | |
Filter | |
≈60mg Human IgG | |
HiScreen MabSelect SuRe LX Prepacked Column | |
10cm | |
Alkali-stabilized Protein A-derived (E. coli) | |
Polypropylene | |
3bar | |
2° to 8°C |
HiScreen MabSelect SuRe LX Prepacked Column | |
1 x 4.7mL | |
0.3 in. | |
0.77cm | |
3.93 in. | |
Designed for method optimization and parameter screening for capture of monoclonal antibodies | |
Epoxy Activation | |
85μm | |
3 to 12 | |
Column |
Sécurité et traitement
Identifiant produit
Mention d'avertissement
Catégorie de danger
Mention de danger
Conseils de prudence
Informations supplémentaires
- HiScreen MabSelect SuRe LX
Mention d'avertissement
- Warning
Catégorie de danger
- Flammable liquid Category 3
Mention de danger
- H226-Flammable liquid and vapour.
Conseils de prudence
- P240-Ground/bond container and receiving equipment.
- P261-Avoid breathing dust/fume/gas/mist/vapours/spray.
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.
Informations supplémentaires
- MIXTURE LIST-Contains : ethanol
- UNKNOWN ACUTE-16.5 per cent of the mixture consists of component(s) of unknown acute toxicity.