Precast Electrophoresis Gels
![](https://assets.fishersci.com/TFS-Assets/CCG/product-images/precast-electrophoresis-gels-header-image.jpg-250.jpg)
Precast Electrophoresis Gels
![](https://assets.fishersci.com/TFS-Assets/CCG/product-images/acrylamide-electrophoresis-gels-header-image.jpg-250.jpg)
![](https://assets.fishersci.com/TFS-Assets/CCG/product-images/agarose-electrophoresis-gels-header-image.jpg-250.jpg)
![](https://assets.fishersci.com/TFS-Assets/CCG/product-images/isoelectric-focusing-(ief)-gels-and-strips-header-image.jpg-250.jpg)
Filtered Search Results
![](/catalog/search/static/resources/images/icons/back_to_top_icon.png)
Thermo Scientific™ TopVision Low Melting Point Agarose
Perform in-gel enzymatic process experiments and nucleic acid recovery after electrophoresis with Thermo Scientific™ TopVision™ Low Melting Point Agarose.
![EDGE](/content/dam/fishersci/glyphs/edge.png)
Invitrogen™ Bolt™ Bis-Tris Plus Resupply Pack, 4 to 12%, WedgeWell™ format
The Bolt Bis-Tris Plus Resupply Pack optimizes your protein separation workflow. This pack includes precast gels, running buffer, and protein ladders, enough for 100 gel runs.
Gel Percentage | 4 to 12% |
---|---|
Separation Range | 3.5 to 260 kDa |
Content And Storage | • Bolt Bis-Tris Plus gels, 10 x 10 gels • Bolt MES Running Buffer (20X), 4 bottles • PageRuler Plus Pre-stained Protein Ladder (10 to 250 kDa) |
Gel Type | Bis-Tris Plus |
For Use With (Equipment) | Mini Gel Tank,XCell SureLock Mini-Cell |
Separation Type | Denaturing |
Quantity | 1 Kit |
Separation of | Protein |
Gel Size | Mini |
Invitrogen™ Novex™ Midi Tris-Glycine Plus Resupply Pack, 10%
The Novex Tris-Glycine Resupply Pack simplifies your protein separation workflow. This pack, sufficient for 100 gel runs, includes precast midi gels, running buffer, and protein ladders.
Gel Percentage | 10% |
---|---|
Separation Range | 30 to 250 kDa |
Content And Storage | • Novex Tris-Glycine gels, 10 x 10 gels • Novex Tris-Glycine Running Buffer (10X), 5 L • PageRuler Plus Pre-stained Protein Ladder (10 to 250 kDa) |
Gel Type | Tris-Glycine Plus |
For Use With (Equipment) | SureLock Tandem Midi Gel Tank,XCell4 SureLock Midi-Cell |
Separation Type | Denaturing, Native |
Quantity | 10 x 10 Gels |
Separation of | Protein |
Gel Size | Midi |
Invitrogen™ NuPAGE™ Midi Bis-Tris Resupply Pack, 4 to 12%
The NuPAGE Bis-Tris Resupply Pack streamlines your protein separation workflow. This pack, sufficient for 100 gel runs, includes precast midi gels, running buffer, and protein ladders.
Gel Percentage | 4 to 12% |
---|---|
Separation Range | 3.5 to 260 kDa |
Content And Storage | • NuPAGE Bis-Tris gels, 10 x 10 gels • NuPAGE MES Running Buffer (20X), 5 bottles • PageRuler Plus Pre-stained Protein Ladder (10 to 250 kDa) |
Gel Type | Bis-Tris |
For Use With (Equipment) | SureLock Tandem Midi Gel Tank,XCell4 SureLock Midi-Cell |
Separation Type | Denaturing |
Quantity | 1 Kit |
Separation of | Protein |
Gel Size | Midi |
Invitrogen™ Novex™ Midi Tris-Glycine Plus Resupply Pack, 4 to 12%
The Novex Tris-Glycine Resupply Pack simplifies your protein separation workflow. This pack, sufficient for 100 gel runs, includes precast midi gels, running buffer, and protein ladders.
Gel Percentage | 4 to 12% |
---|---|
Separation Range | 20 to 250 kDa |
Content And Storage | • Novex Tris-Glycine gels, 10 x 10 gels • Novex Tris-Glycine Running Buffer (10X), 5 L • PageRuler Plus Pre-stained Protein Ladder (10 to 250 kDa) |
Gel Type | Tris-Glycine Plus |
For Use With (Equipment) | SureLock Tandem Midi Gel Tank,XCell4 SureLock Midi-Cell |
Separation Type | Denaturing, Native |
Quantity | 10 x 10 Gels |
Separation of | Protein |
Gel Size | Midi |
Invitrogen™ NuPAGE™ Midi Tris-Acetate Resupply Pack, 3 to 8%
The NuPAGE Tris-Acetate Resupply Pack simplifies your large molecular weight protein separation workflow. This pack, sufficient for 100 gel runs, includes precast midi gels, running buffer, and protein ladders.
Gel Percentage | 3 to 8% |
---|---|
Separation Range | 36 to 500 kDa |
Content And Storage | • NuPAGE Tris-Acetate gels, 10 x 10 gels • NuPAGE Tris-Acetate Running Buffer (20X), 5 bottles • HiMark Pre-stained Protein Standard (30 to 460 kDa), 4 vials |
Gel Type | Tris-Acetate |
For Use With (Equipment) | SureLock Tandem Midi Gel Tank,XCell4 SureLock Midi-Cell |
Separation Type | Denaturing, Native |
Quantity | 1 Kit |
Separation of | Protein |
Gel Size | Midi |
Invitrogen™ NuPAGE™ Bis-Tris Resupply Pack, 4 to 12%
The NuPAGE Bis-Tris Resupply Pack streamlines your protein separation workflow. This pack, sufficient for 100 gel runs, includes precast mini gels, running buffer, and protein ladders.
Gel Percentage | 4 to 12% |
---|---|
Separation Range | 3.5 to 260 kDa |
Content And Storage | • NuPAGE Bis-Tris gels, 10 x 10 gels • NuPAGE MES Running Buffer (20X), 4 bottles • PageRuler Plus Pre-stained Protein Ladder (10 to 250 kDa) |
Gel Type | Bis-Tris |
For Use With (Equipment) | Mini Gel Tank,XCell SureLock Mini-Cell |
Separation Type | Denaturing |
Quantity | 1 Kit |
Separation of | Protein |
Gel Size | Mini |
Invitrogen™ Novex™ Tris-Glycine Resupply Pack, 4 to 20%, Wedgewell™ format
The Novex Tris-Glycine Resupply Pack simplifies your protein separation workflow. This pack, sufficient for 100 gel runs, includes precast mini gels, running buffer, and protein ladders.
Gel Percentage | 4 to 20% |
---|---|
Separation Range | 20 to 200 kDa |
Gel Type | Tris-Glycine Plus |
For Use With (Equipment) | Mini Gel Tank,XCell SureLock Mini-Cell |
Separation Type | Denaturing, Native |
Quantity | 1 Kit |
Separation of | Protein |
Gel Size | Mini |
Invitrogen™ NuPAGE™ Tris-Acetate Resupply Pack, 3 to 8%
The NuPAGE Tris-Acetate Resupply Pack simplifies your large molecular weight protein separation workflow. This pack, sufficient for 100 gel runs, includes precast mini gels, running buffer, and protein ladders.
Gel Percentage | 3 to 8% |
---|---|
Separation Range | 40 to 500 kDa |
Content And Storage | • NuPAGE Tris-Acetate gels, 10 x 10 gels • NuPAGE Tris-Acetate Running Buffer (20X), 4 bottles • HiMark Pre-stained Protein Standard (30 to 460 kDa), 4 vials |
Gel Type | Tris-Acetate |
For Use With (Equipment) | Mini Gel Tank,XCell SureLock Mini-Cell |
Separation Type | Denaturing, Native |
Quantity | 1 Kit |
Separation of | Protein |
Gel Size | Mini |
Invitrogen™ NuPAGE™ Midi Bis-Tris Resupply Pack, 10%
The NuPAGE Bis-Tris Resupply Pack streamlines your protein separation workflow. This pack, sufficient for 100 gel runs, includes precast midi gels, running buffer, and protein ladders.
Gel Percentage | 10% |
---|---|
Separation Range | 3.5 to 260 kDa |
Content And Storage | • NuPAGE Bis-Tris gels, 10 x 10 gels • NuPAGE MES Running Buffer (20X), 5 bottles • PageRuler Plus Pre-stained Protein Ladder (10 to 250 kDa) |
Gel Type | Bis-Tris |
For Use With (Equipment) | SureLock Tandem Midi Gel Tank,XCell4 SureLock Midi-Cell |
Separation Type | Denaturing |
Quantity | 10 x 10 Gels |
Separation of | Protein |
Gel Size | Midi |
Invitrogen™ Novex™ Midi Tris-Glycine Plus Resupply Pack, 4 to 20%
The Novex Tris-Glycine Resupply Pack simplifies your protein separation workflow. This pack, sufficient for 100 gel runs, includes precast midi gels, running buffer, and protein ladders.
Gel Percentage | 4 to 20% |
---|---|
Separation Range | 20 to 200 kDa |
Content And Storage | • Novex Tris-Glycine gels, 10 x 10 gels • Novex Tris-Glycine Running Buffer (10X), 5 L • PageRuler Plus Pre-stained Protein Ladder (10 to 250 kDa) |
Gel Type | Tris-Glycine Plus |
For Use With (Equipment) | SureLock Tandem Midi Gel Tank,XCell4 SureLock Midi-Cell |
Separation Type | Denaturing, Native |
Quantity | 1 Kit |
Separation of | Protein |
Gel Size | Midi |
Invitrogen™ E-Gel™ EX Double Comb Agarose Gels
Invitrogen E-Gel EX Double Comb precast agarose gels are designed for ultrasensitive and convenient DNA sample electrophoresis in as little as 5 to 8 minutes.
Gel Type | E-Gel |
---|---|
Product Type | Agarose Gel |
Well Design | Double Comb |
Stain Type | SYBR™ Gold |
Wells | 22-well |
Invitrogen™ Novex™ Tricine Welcome Pack and Mini Blot Modules, 10–20%
The Novex Tricine Welcome Pack and Mini Blot Modules provide all of the necessary Novex gels and buffers needed to begin using the Mini Gel Tank plus two Mini Blot Modules for wet transfer. Each Mini Gel Tank can accommodate up to two gels per run or up to two Mini Blot Modules for wet transfer.
Gel Percentage | 10 to 20% |
---|---|
Separation Range | 2.5 to 200 kDa |
Gel Type | Tricine |
For Use With (Equipment) | Mini Gel Tank |
Separation Type | Denaturing |
Separation of | Protein |
Gel Size | Mini |
Invitrogen™ Novex™ pH 3-10 IEF Protein Gels, 1.0 mm
Novex™ pH 3-10 IEF Gels are used for pI determination and are excellent for native applications using soluble proteins. Isoelectric focusing (IEF) is an electrophoresis technique that separates proteins based on their isoelectric point (pI).
![EDGE](/content/dam/fishersci/glyphs/edge.png)
Gel Type | IEF |
---|---|
Quantity | 5 Gels/Box |
GelThickness | 1.0 mm |
Storage Requirements | Store at 2°C to 8°C. Do not freeze. |
Invitrogen™ NuPAGE™ 4 to 12%, Bis-Tris, 1.0 mm, Mini Protein Gel, 12-well
Invitrogen NuPAGE Bis-Tris protein gels are precast polyacrylamide gels that provide broad molecular weight protein separation with high resolution and sample integrity.