Filtered Search Results
Search results for "memmert climate chamber"
Memmert™ Constant Climate Chambers HPPeco with Advanced Peltier Technology
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Ideal for Q1A ICH-compliant stability tests, durability tests in the fields of pharmaceuticals, food and cosmetics, as well as quality tests and humidity-controlled storage.
Type | Climate Chamber |
---|---|
Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
Humidity Source | Humidity supply with distilled water from external tank by self-priming pump |
Relative Humidity | 10 to 90% |
Lighting | Optional Illumination Unit |
Chamber Material | Stainless Steel (304/1.4301) |
Frequency | 50/60 Hz |
Compressor | No |
Material | Stainless Steel |
Certifications/Compliance | CE |
Display | 2 high-definition TFT-color displays (TwinDISPLAY) |
Memmert™ Climate Chamber ICH
Ideal for stability testing according to ICH, WHO, EMA, ASEAN, GMP, GLP and GCCP.
Plug Type | German Type |
---|---|
Relative Humidity | 10 to 80% |
Refrigerant | R134a |
Controller Type | TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller |
Humidity Range | 10 to 80% |
For Use With (Application) | Analytical Chemistry, Manufacturing, Microbiology, Research Chemistry, Temperature Control, Food & Beverage, Pharmaceuticals, Mining |
Convection Type | Forced |
Alarm Types | Audible and visual |
Temperature Control | Adaptive multifunctional digital PID-microprocessor controller |
Accuracy | 0.1°C |
Humidity Accuracy | 1% |
Lighting | Optional Illumination Unit |
Voltage | 115/230 V |
Frame Material | Stainless Steel |
Humidity Display | 2 high-definition TFT-colour displays (TwinDISPLAY) |
Certifications/Compliance | CE |
Shipping Condition | The appliances must be transported upright |
Electrical Requirements | 230 V, 50/60 Hz |
Warranty | 3 years |
Chamber Material | Stainless Steel (304/1.4301) |
Port Size | 40 mm clear diameter |
Sensor Types | Temperature Sensor 2 Pt100 Sensors DIN Class A |
Temperature Stability | ±0.1°C |
Quantity | 1 Ea. |
Compressor | Yes |
Material | Stainless Steel |
Shelf Material | Stainless Steel |
Protection Class | Mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature; over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display |
Temperature Sensor | 2 Pt100 Class A in 4-wire circuit |
Type | Climate Chamber |
Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
Humidity Source | Humidity supply with distilled water from external tank by self-priming pump |
No. of Grids | 2 |
Frequency | 50/60 Hz |
Temperature Range (Metric) | -10°C to +60°C |
Temperature Resolution | 0.1°C |
Resolution | Resolution of display 0.1 % |
Programmability | AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port |
Product Line | Climate Chamber |
Display | 2 high-definition TFT-colour displays (TwinDISPLAY) |
Memmert™ Climate Chamber ICH with Illumination Unit
Ideal for stability testing according to ICH guideline Q1B, option 2 (photostability).
Plug Type | German Type |
---|---|
Relative Humidity | 10 to 80% |
Refrigerant | R134a |
Controller Type | TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller |
Humidity Range | 10 to 80% |
For Use With (Application) | Analytical Chemistry, Manufacturing, Microbiology, Research Chemistry, Temperature Control, Food & Beverage, Pharmaceuticals, Mining |
Convection Type | Forced |
Includes | Illumination: 2 Fluorescent lights with UV lamps (spectral range of 315 to 400 nm), 4 fluorescent lights with cold white light (standard illuminant D65, 6.5 K) |
Alarm Types | Audible and visual |
Temperature Control | Adaptive multifunctional digital PID-microprocessor controller |
Accuracy | 0.1°C |
Humidity Accuracy | 1% |
Lighting | Illumination Unit |
Voltage | 115/230 V |
Frame Material | Stainless Steel |
Humidity Display | 2 high-definition TFT-colour displays (TwinDISPLAY) |
Certifications/Compliance | CE |
Shipping Condition | The appliances must be transported upright |
Electrical Requirements | 230 V, 50/60 Hz |
Warranty | 3 years |
Chamber Material | Stainless Steel (304/1.4301) |
Port Size | 40 mm clear diameter |
Sensor Types | Temperature Sensor 2 Pt100 Sensors DIN Class A |
Temperature Stability | ±0.1°C |
Quantity | 1 Ea. |
Compressor | Yes |
Material | Stainless Steel |
Shelf Material | Stainless Steel |
Protection Class | Mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature; over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display |
Temperature Sensor | 2 Pt100 Class A in 4-wire circuit |
Type | Climate Chamber |
Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
Humidity Source | Humidity supply with distilled water from external tank by self-priming pump |
No. of Grids | 2 |
Frequency | 50/60 Hz |
Temperature Range (Metric) | 0°C to +60°C |
Temperature Resolution | 0.1°C |
Resolution | Resolution of display 0.1 % |
Programmability | AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port |
Product Line | Climate Chamber |
Display | 2 high-definition TFT-colour displays (TwinDISPLAY) |
Memmert™ Iq/Oq Document W/Device-Specific Works Test Data (Temperature And Humidity Value), For Hcp150
Includes temperature distribution survey for one free-selectable temperature and humidity value.
Memmert™ Iq/Oq Document W/Device-Specific Works Test Data (Temperature And Humidity Value), For Hcp105
Includes temperature distribution survey for one free-selectable temperature and humidity value.
Memmert™ Iq/Oq Document W/Device-Specific Works Test Data (Temperature And Humidity Value), For Hcp50
Includes temperature distribution survey for one free-selectable temperature and humidity value.
Memmert™ Iq/Oq Document W/Device-Specific Works Test Data (Temperature And Humidity Value), For Hcp240
Includes temperature distribution survey for one free-selectable temperature and humidity value.
Memmert™ Iq/Oq Document W/Device-Specific Works Test Data (Temperature And Humidity Value), For Ich260
Includes temperature distribution survey for one free-selectable temperature and humidity value.
Memmert™ Iq/Oq Document W/Device-Specific Works Test Data (Temperature And Humidity Value), For Ich750
Includes temperature distribution survey for one free-selectable temperature and humidity value.
Memmert™ Iq Document With Device-Specific Works Test Data For Validation By Customer, For Un55Pa
Includes IQ document with works test data for chamber.
Memmert™ Iq Document With Device-Specific Works Test Data For Validation By Customer, For Hcp105
Includes IQ document with works test data for chamber.
Memmert™ Iq Document With Device-Specific Works Test Data For Validation By Customer, For If450Bw
Includes IQ document with works test data for chamber.
Memmert™ Iq Document With Device-Specific Works Test Data For Validation By Customer, For If110Bw
Includes IQ document with works test data for chamber.
Memmert™ Iq Document With Device-Specific Works Test Data For Validation By Customer, For Uf160Ts
Includes IQ document with works test data for chamber.
Memmert™ Iq Document With Device-Specific Works Test Data For Validation By Customer, For Un75Pa
Includes IQ document with works test data for chamber.