Fisherbrand™ accumet™ AB250 Benchtop pH/ISE Meters
Provides intuitive, simple operation and high accuracy measurements in a compact, affordable meter. Fisherbrand accumet AB250 pH/ISE meter provides flexible measurements of pH or ion concentration using an ion selective electrode (ISE) in one easy to use, reliable measurement system.
Accuracy (mV) | ±0.2 mV |
---|---|
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Calibration Points (ISE) | 2 to 6 points from one of following group, 0.001, 0.01, 0.1, 1, 10, 100, 0.01, 0.1, 1, 10, 100, 1000 |
Resolution (pH) | 0.1/0.01/0.001 |
Range (pH) | -2 to 20 |
Resolution (ISE) | 0.001/0.01/0.1/1 (automatic) |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.001 to 19999 (±2000) |
Data Management Details | Manual, timed (selectable every 3 to 3600 sec.), printer or CSV format |
Display Type | LCD |
Voltage | 100/240V |
Resolution (mV) | 0.1mV |
Outputs | RS232 (phono plug), mini-B USB, stirrer |
Frequency | 50/60Hz |
Data Points | 500 |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Range (mV) | ±2000 mV |
Inputs | BNC, ATC |
Temperature Resolution | 0.1°C |
Thermo Scientific™ Elite pH Spear Pocket Testers and Replacement Sensors
Flexible on-the-go pH testing using durable Elite spear pocket testers with replaceable sensors for a variety of applications include food, beverage, agriculture and more!
Temperature Accuracy | Manual input |
---|---|
Temperature Range (English) | 32.0°F to 140.0°F |
Resolution (pH) | 0.01 |
Measurement Modes | pH |
Range (pH) | -1 to 15 |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | 0.0°C to 60.0°C |
Accuracy (pH) | ±0.02 |
Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Get premium performance and flexibility with our multiparameter benchtop meter with pH/ISE, conductivity and RDO/DO modules to measure up to four channels at once.
Power Rating | DC input: 9VDC, 1A |
---|---|
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
Resolution (Polarographic DO) | 0.01, 0.1mg/L |
Pressure Range | 400 to 850mmHg |
Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature,TDS,Conductivity,Salinity |
Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
Power Supply | Universal AC adapter (included) |
Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Color graphic LCD with user-customizable options |
Resolution (mV) | 0.1mV |
Data Points | 2000 with date and time stamp |
Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Calibration Points (ISE) | 1 to 6 |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
Relative Humidity Range | 5 to 85%, non-condensing |
Range (RDO) | 0.00 to 50.00mg/L |
Dimensions (L x W x H) | 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Percent Saturation Range (RDO) | 0.0 to 500.0% saturation |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB (2), RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 6 |
Backlight Option | Yes |
Percent Saturation Relative Accuracy (RDO) | ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation |
Range (Polarographic DO) | 0.00 to 90.00mg/L |
Range (mV) | ±2000.0 mV |
Accuracy (Barometer) | ±6 mmHg |
Range (ORP) | ±2000.0 mV |
Pressure Resolution | 0.1mmHg |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5°, 10°, 15°, 20°, 25°C |
Range (pH) | -2.000 to 20.000 |
TDS Factor Range | Linear (0.02 to 9.99) |
Channels | 4 - customizable with modules |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Resolution (RDO) | 0.01, 0.1mg/L |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Calibration Points (Conductivity) | Up to 6 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
Accuracy (Polarographic DO) | ±0.2 mg/L or ±2% of reading, whichever is greater |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Range (TDS) | 0.001 ppm to 200.0 ppt |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
IP Rating | IP 54 |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Percent Saturation Range (Polarographic DO) | 0.0 to 600.0% saturation |
Temperature Resolution | 0.1°C, 0.1°F |
Accuracy (RDO) | ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L |
Hanna Instruments™ Waterproof pH/Conductivity/TDS Tester
Makes measuring pH quick and easy. Hanna Instruments™ Waterproof pH/Conductivity/TDS Tester is lightweight and waterproof offering high accuracy pH, EC/TDS and temperature measurements in a single handheld unit.
Thermo Scientific™ Elite pH Pocket Testers and Replacement Sensors
Flexible on-the-go pH and temperature testing using durable Elite pocket testers with replaceable sensors for a variety of applications including environmental monitoring, pools, spas and more!
Thermo Scientific™ Elite PCTS pH / Conductivity / TDS / Salinity Pocket Testers and Replacement Sensors
Flexible on-the-go pH, conductivity, TDS, salinity and temperature testing using durable Elite PCTS pocket testers for a variety of applications including agriculture, aquaculture, hydroponics and more!
Salinity Measurement Modes | Per practical salinity curve |
---|---|
Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
Range (Conductivity) | 0.00 to 20.00 mS/cm |
Resolution (pH) | 0.01 |
Range (TDS) | 0.00 to 10.00 ppt |
Measurement Modes | pH,Conductivity,TDS,Salinity,Temperature |
Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
Range (pH) | -1.00 to 15.00 |
TDS Factor Range | 0.40 to 1.00 (selectable) |
Accuracy (pH) | ±0.02 |
Relative Humidity Range | 5 to 85 %, non-condensing |
Range (Salinity) | 0.00 to 10.00 ppt |
Temperature Compensation | Yes |
Accuracy (TDS) | ± 1% full scale |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.10 ppt |
Accuracy (Conductivity) | ± 1% full scale |
Temperature Range (English) | 32.0°F to 140.0°F |
Calibration Points (pH) | 1 to 3 |
Calibration Modes | pH, conductivity, TDS, salinity, temperature |
Temperature Probe Calibration | 1 point |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Resolution | 0.1°C, 0.1°F |
Calibration Points (Conductivity) | 1 to 3 |
Thermo Scientific™ Orion™ Dual Star™ pH, ISE, mV, ORP and Temperature Dual Channel Benchtop Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Accurately monitor pH, ion concentration, mV, ORP and temperature on two channels with our pH/ISE benchtop meter for advanced lab analysis.
Temperature (Metric) Range | -5.0°C to +105.0°C |
---|---|
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
Resolution (pH) | 0.1, 0.01, 0.001 |
Languages | English, Spanish, French, Italian and German |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
Range (pH) | -2.000 to 19.999 |
Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
Channels | 2 |
Accuracy (pH) | ±0.002 |
Power Supply | Universal AC adapter (included) |
Range (ISE) | 0.0001 to 19,900 in ppm, M, mg/L, % or unit-less |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Graphic LCD with Backlight |
Resolution (mV) | 0.1 mV |
Data Points | 1000 with date and time stamp |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Inputs | Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.1°C |
Weight (Metric) | 0.9 kg |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Electrical Requirements | 90 to 260 VAC 50/60 Hz |
Warranty | 3 Year Meter Warranty |
Stability | Smart Stability and Smart Averaging |
Calibration Points (ISE) | 2 to 6 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Isopotential Point | 7.000 pH (adjustable), 1.000 ISE (adjustable) |
AC Adapter | Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003) |
Log Function Type | Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Relative Humidity Range | 5 to 85 %, non-condensing |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | High/low limit alarm |
Dimensions (L x W x H) | 24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.) |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Model | Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter |
Outputs | USB, RS232 |
Range (Relative mV) | ±1999.9 mV |
Calibration Points (pH) | 1 to 6 |
Backlight Option | Yes, adjustable |
Weight (English) | 2 lb. |
Resolution (Temperature) | 0.1°C, 0.1°F |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Range (mV) | ±1999.9 mV |
Range (ORP) | ±1999.9 mV |
Methods | 10 per channel with password protection |
Thermo Scientific™ Eutech™ ECTestr11+ Multi Range Conductivity Tester
Get quick and accurate conductivity measurements in the field, laboratories, and schools.
Fisherbrand™ Traceable™ Expanded Range Conductivity Meter
Ideal for checking the purity of water from stills, deionizers, and reverse osmosis, testing laboratory glassware rinsing, measuring total dissolved solids, and making solutions.
Thermo Scientific™ Orion Star™ A214 pH/ISE Benchtop Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Reliably measure pH, ion concentration, mV, ORP and temperature with our pH/ISE benchtop meter for advanced lab analysis and interfacing.
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
---|---|
Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
Data Management Details | Transfer single, range or all data points to printer or computer |
Battery Life | 800 hr. |
Display Type | LCD Graphic, Backlit |
Resolution (mV) | 0.1mV |
Data Points | 2000 with date and time stamp |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Warranty | 3 Year Meter |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Calibration Points (ISE) | 1 to 5 |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Battery Type | 4 AA (sold separately) |
Relative Humidity Range | 5 to 85 %, non-condensing |
Dimensions (L x W x H) | 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.) |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 5 |
Backlight Option | Yes, selectable |
Range (mV) | ±2000.0 mV |
Range (ORP) | ±2000.0 mV |
Methods | 10 per channel with password protection |
Range (pH) | -2.000 to 20.000 |
Channels | 1 |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
Inputs | BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Weight (Metric) | 0.9 kg |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Isopotential Point | 7.000pH |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP 54 |
Model | Orion Star A214 pH/ISE/mV/RmV/ORP/Temperature Benchtop Meter |
Weight (English) | 2 lb. |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Temperature Resolution | 0.1°C, 0.1°F |
Eutech Expert pH Pocket Tester
Perform on-the-go, fuss-free measurements for applications such as water treatment, environmental monitoring, education, hydroponics, agriculture, aquaculture, food & beverage and many more!
Fisherbrand™ Traceable™ Conductivity Meter Pen
Easy-to-use, waterproof conductivity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Thermo Eutech™ COND 6+ Conductivity Meter
COND 6+ Conductivity Meter, Rubber Armour/Stand, electrode CONSEN91B
Thermo Scientific™ Eutech™ ORPTestr10 ORP Meter
Eutech offers a wide range of ORP meters that measure both pH and ORP values in various educational, laboratory and industrial applications.
Thermo Scientific™ Eutech COND 6+ Handheld Meter Kit with Electrode
Lightweight, economical, and efficient handheld meters