TLC Plates
TLC Plates
- (5)
- (10)
- (2)
- (4)
- (1)
- (11)
- (2)
- (11)
- (3)
- (63)
- (3)
- (1)
- (10)
- (1)
- (1)
- (3)
- (52)
- (2)
- (25)
- (73)
- (2)
- (2)
- (5)
- (32)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (37)
- (139)
- (45)
- (75)
- (1)
- (4)
- (1)
- (1)
- (2)
- (8)
- (1)
- (1)
- (7)
- (1)
- (2)
- (3)
- (2)
- (4)
- (4)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (1)
- (4)
- (5)
- (38)
- (2)
- (1)
- (5)
Filtered Search Results
Macherey-Nagel™ Standard SIL G Silica Layers on Alugram™ Aluminum Sheets UV254
Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G Silica Layers on Alugram™ Aluminum Sheets UV254 come in a variety of sizes.
Specific Surface | ∼500 m2/g |
---|---|
Pore Size | 60 Å |
Particle Size | 5 to 17 μm |
Pore Volume | 0.75 mL/g |
Fluorescent Indicator | UV254 |
Macherey-Nagel™ Standard SIL G Silica Layers on Polygram™ polyester sheets
Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on Polygram™ polyester sheets come in a variety of sizes. Select fluorescent indicator and choose from a variety of pack sizes.
Thickness (Metric) | 0.2 mm |
---|---|
Pore Size | 60 Å |
Type | Polyester Sheet |
Pore Volume | 0.75 mL/g |
Fluorescent Indicator | UV254 |
Macherey-Nagel™ Xtra SIL G Silica Layers on Alugram™ Aluminum Sheets UV254
Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Xtra SIL G Silica Layers on Alugram™ Aluminum Sheets UV254 come in a variety of sizes.
Thickness (Metric) | 0.20 mm |
---|---|
Specific Surface | ∼500 m2/g |
Pore Size | 60 Å |
Particle Size | 5 to 17 μm |
Type | Aluminum Sheet |
Pore Volume | 0.75 mL/g |
Fluorescent Indicator | UV254 |
Macherey-Nagel™ ALUGRAM™ Xtra SIL G Aluminum Sheets
Stable in almost all organic solvents and in purely aqueous eluents. Macherey-Nagel™ ALUGRAM™ Xtra SIL G Aluminum Sheets are unmodified standard silica layers on aluminum for use in TLC. Feature outstanding wettability and improved cutting properties.
Thickness (Metric) | 0.20 mm |
---|---|
Specific Surface | ∼500 m2/g |
Pore Size | 60 Å |
Particle Size | 5 to 17 μm |
Type | Aluminum Sheet |
Material | Alugram Aluminum Sheets with IUInmodified Silica 60 Layers |
Pore Volume | 0.75 mL/g |
Macherey-Nagel™ Alugram™ RP-18 W/UV254 Modified Silica Phase
For use in normal or reverse phase HPTLC. Macherey-Nagel™ Alugram™ RP-18 W/UV254 Modified Silica Phase are aluminum sheets coated with wettable layers of modified nano silica that can be developed with purely organic and organic/aqueous solvents and purely aqueous eluents.
Thickness (Metric) | 0.15 mm |
---|---|
Specific Surface | ∼500 m2/g |
Pore Size | 60 Å |
Particle Size | 2 to 10 μm |
Type | TLC Plate |
For Use With (Application) | Aminophenols, Barbiturates, Preservatives, Nucleobases, Polycyclic Aromatic Hydrocarbons, Steroids, Tetracyclines, Plasticizers (Phthalates) |
Pore Volume | 0.75 mL/g |
Fluorescent Indicator | UV254 |
Macherey-Nagel™ RP-18 W/UV254 Glass HPTLC Plates
Designed for use in HPTLC. Macherey-Nagel™ RP-18 W/UV254 Glass HPTLC Plates have a layer of modified nano silica with a fluorescent indicator for short-wave UV (254nm). It is wettable with water, acid-resistant and stable at pH 2–10.
Macherey-Nagel™ Standard SIL G Silica Layers on Alugram™ Aluminum Sheets
Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G Silica Layers on Alugram™ Aluminum Sheets come in a variety of sizes.
Thickness (Metric) | 0.2 mm |
---|---|
Specific Surface | ∼500 m2/g |
Pore Size | 60 Å |
Particle Size | 5 to 17 μm |
Type | TLC Plate |
For Use With (Application) | Thin Layer Chromatography (TLC) |
Pore Volume | 0.75 mL/g |
MP Biomedicals™ EcoChrome™ Silica TLC Plate
Used as a defoamer component. In hydrated form, it is used in toothpaste as a hard abrasive to remove tooth plaque. SiO
Macherey-Nagel™ Standard SIL G Silica Layers on Glass Plates
Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on glass plates come in a variety of plate sizes and layer thicknesses. Select a fluorescent indicator and choose from a variety of pack sizes.
Specific Surface | ∼500 m2/g |
---|---|
Pore Size | 60 Å |
Particle Size | 5 to 17 μm |
Type | Glass Plate |
Material | Silica 60 |
Pore Volume | 0.75 mL/g |
Macherey-Nagel™ Nano-SIL NH2 ALUGRAM™ Aluminum Sheets
Designed for use in high-performance thin layer chromatography (HPTLC). Macherey-Nagel™ Nano-SIL NH2 ALUGRAM™ Aluminum Sheets include amino-modified silica layers and a fluorescent indicator at short-wave UV (254nm).
Macherey-Nagel™ Adamant™ Unmodified Standard Silica Layers for TLC, UV254
Increase separation efficiency and maximize resolution during TLC (thin-layer chromatography). Adamant™ Unmodified Standard Silica Layers for TLC, UV254, are available on glass plates with an optimized binder system and UV indicator.
Thickness (Metric) | 0.25 mm |
---|---|
Specific Surface | ∼500 m2/g |
Pore Size | 60 Å |
Particle Size | 5 to 17 μm |
Type | Glass Plate |
Pore Volume | 0.75 mL/g |
Fluorescent Indicator | UV254 |
Macherey-Nagel™ Polygram Alox N/UV254 Polyester Sheets
Macherey-Nagel Polygram Alox N/UV254 Polyester Sheets, Dimensions: 4 x 8 cm, Pore Size: 60 A, Fluorescent Indicator: UV254, Thickness: 0.2 mm
Thickness (Metric) | 0.2 mm |
---|---|
Pore Size | 60 Å |
Type | Polyester Sheet |
Fluorescent Indicator | UV254 |
Macherey-Nagel™ ALUGRAM™ Alox N/UV254 Aluminum Sheets
Designed for use in thin layer chromatography. Macherey-Nagel™ ALUGRAM™ Alox N/UV254 Aluminum Sheets include aluminum oxide layers and a fluorescent indicator at short-wave UV (254nm). Activating the layers before use is recommended.
Thickness (Metric) | 0.2 mm |
---|---|
Specific Surface | ∼200 m2/g |
Pore Size | 60 Å |
Type | TLC Plate |
Material | Aluminum Sheets Alugram Alox N |
For Use With (Application) | Terpenes, Alkaloids, Steroids, Aliphatic and Aromatic Compounds |
Fluorescent Indicator | UV254 |
Macherey-Nagel™ SIL G-25 / UV254 Glass Plates
Stable in almost all organic solvents. Macherey-Nagel™ SIL G-25 / UV254 Glass Plates are analytical plates with unmodified standard silica layers on glass for use in TLC. Feature a green fluorescence indicator for short-wave UV.
Thickness (Metric) | 0.25 mm |
---|---|
Specific Surface | ∼500 m2/g |
Pore Size | 60 Å |
Particle Size | 5 to 17 μm |
Type | Glass TLC Plate |
Material | Glass Plates with Unmodified Silica 60 Layers |
Pore Volume | 0.75 mL/g |
Fluorescent Indicator | UV254 |