HPLC Columns and Cartridges
HPLC Columns and Cartridges
Filtered Search Results
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
Pore Size | 100 Å |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
USP Type | L1 |
Thermo Scientific™ Acclaim™ C30 HPLC Columns
Use for superior separation of hydrophobic structural isomers.
Pore Size | 200 Å |
---|---|
Carbon Load | 13% |
Stationary Phase | C30 |
Temperature | 60°C |
Phase | Reversed Phase |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 200 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
Pore Size | 120 Å |
---|---|
Carbon Load | 18% |
Stationary Phase | C18 |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L1 |
Thermo Scientific™ Acclaim™ Surfactant Plus HPLC Columns
Use for simultaneous separation of anionic, nonionic, cationic, and amphoteric surfactants with CAD and LC-MS detection.
Pore Size | 120 Å |
---|---|
Stationary Phase | Proprietary |
Temperature | 50°C |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Specialty/Application Specific |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Organic Acid HPLC Columns
Use for separation of hydrophilic, aliphatic, and aromatic organic acids.
Pore Size | 120 Å |
---|---|
Carbon Load | 17% |
Stationary Phase | Proprietary |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 2 to 8 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Polar Advantage II HPLC Columns
Resolve polar and nonpolar compounds in a single run. These columns have high pH stability (pH 1.5–10) in the separation of basic, neutral, and acidic species.
Pore Size | 120 Å |
---|---|
Stationary Phase | Polar Embedded |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Reversed Phase |
Surface Area | 300 m²/g |
USP Type | L60 |
Thermo Scientific™ Acclaim™ Trinity P1 HPLC Columns
Use these mixed-mode columns for simultaneous separation of pharmaceutical drug substances and their counter ions with high efficiency.
Pore Size | 300 Å |
---|---|
Particle Size | 3 μm |
Stationary Phase | Reversed Phase/Anion Exchange/Cation Exchange |
Temperature | 45°C |
Phase | Reversed Phase and Ion Exchange |
Endcapped | Proprietary |
Column Type | Mixed Mode |
pH | 2.5 to 7 |
Surface Area | 100 m²/g |
Max. Pressure | 4500 psi (310 bar) |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ AmG C18 HPLC Columns
Meet today’s demands for aminoglycoside antibiotic analyses, including drug purity characterization & quantification. They have unique tolerance to harsh conditions.
Pore Size | 120 Å |
---|---|
Particle Size | 3 μm |
Stationary Phase | C18 |
Temperature | <80°C |
Phase | Reversed Phase |
Packing Material | Spherical, High Purity Silica |
Column Type | Aminoglycoside Analysis |
pH | 0.5 to 10 |
Max. Pressure | 8000 psi (550 bar) |
Product Line | Acclaim |
USP Type | L1 |
Thermo Scientific™ Acclaim™ Trinity P2 HPLC Columns
Use these mixed-mode columns for separation of multivalent cations or anions and pharmaceuticals.
Pore Size | 300 Å |
---|---|
Solvents | Compatible with most common HPLC organic solvents except for alcohols |
Stationary Phase | Spherical, Nanopolymer Hybrid Silica |
Temperature | 45°C |
Phase | HILIC and Ion Exchange |
Endcapped | Proprietary |
Column Type | Mixed Mode |
Surface Area | 100 m²/g |
Max. Pressure | 6000 psi (415 bar) |
Particle Size | 3 μm |
Mobile Phase Compatibility | 0 to 100% aqueous mobile phase |
pH | 2.5 to 7 |
Particle Shape | Spherical silica |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ HILIC-10 HPLC Columns
Use this HILIC column to retain and separate highly polar molecules that are unretained by reversed-phase chromatography.
Pore Size | 120 Å |
---|---|
Carbon Load | 8% |
Stationary Phase | Proprietary |
Temperature | 70°C |
Phase | HILIC |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | HILIC |
pH | 2 to 8 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Carbamate HPLC Columns
Achieve baseline separation of carbamate specified in U.S. EPA Method 531.2 with high-efficiency Thermo Scientific™ Acclaim™ Carbamate LC Columns.
Pore Size | 120 Å |
---|---|
Stationary Phase | Proprietary |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 3 to 7 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ 300 C18 HPLC Columns
Use these wide-pore C18 columns to achieve high-resolution protein separations.
Pore Size | 300 Å |
---|---|
Particle Size | 3 μm |
Flow Rate | 1 mL/min. |
Carbon Load | 8% |
Stationary Phase | C18 |
Temperature | 60°C |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2.5 to 7.5 |
Surface Area | 100 m²/g |
Product Line | Acclaim |
USP Type | L1 |
Thermo Scientific™ Acclaim™ Polar Advantage HPLC Columns
Use for reversed-phase separation of basic or pharmaceutical compounds using highly aqueous mobile phases.
Pore Size | 120 Å |
---|---|
Carbon Load | 17% |
Stationary Phase | Polar Embedded |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L60 |
Thermo Scientific™ Acclaim™ Surfactant HPLC Columns
Use for outstanding separation of anionic, nonionic, and cationic surfactants with ELSD and RI detectors.
Pore Size | 120 Å |
---|---|
Carbon Load | 12% |
Stationary Phase | Proprietary |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Explosives E2 HPLC Columns
Use for baseline resolution of all 14 explosives listed in EPA Method 531.2.
Pore Size | 120 Å |
---|---|
Stationary Phase | Proprietary |
Temperature | 50°C |
Phase | Reversed Phase |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |