Western Blot and Nucleic Acid Membranes and Filter Paper
Western Blot and Nucleic Acid Membranes and Filter Paper
- (7)
- (16)
- (1)
- (3)
- (12)
- (1)
- (1)
- (3)
- (5)
- (4)
- (3)
- (9)
- (1)
- (1)
- (3)
- (57)
- (12)
- (11)
- (1)
- (11)
- (87)
- (7)
- (1)
- (10)
- (1)
- (13)
- (1)
- (55)
- (21)
- (118)
- (1)
- (1)
- (29)
- (7)
- (94)
- (123)
- (1)
- (12)
- (3)
- (1)
- (2)
- (1)
- (1)
- (6)
- (5)
- (12)
- (2)
- (2)
- (2)
- (11)
- (1)
- (3)
- (1)
- (27)
- (1)
- (2)
- (1)
- (2)
- (5)
- (1)
- (1)
- (13)
- (1)
- (1)
- (21)
- (2)
- (2)
- (2)
- (5)
- (1)
- (4)
- (10)
- (29)
- (4)
- (1)
- (5)
- (1)
- (8)
- (1)
- (17)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (4)
- (3)
- (1)
- (11)
- (2)
- (3)
- (1)
- (32)
- (1)
- (2)
- (1)
- (3)
- (2)
- (1)
- (17)
- (3)
- (12)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (2)
- (4)
- (1)
- (5)
- (1)
- (2)
- (31)
- (4)
- (7)
- (8)
- (1)
- (13)
- (1)
Filtered Search Results
Cytiva Whatman™ Grade GB005 Blotting Paper
Recommended for applications where fewer layers of blotting paper must still ensure a high capacity. Whatman™ Grade GB005 Blotting Paper ensures the wicking capability and uniformity of capillary action that are important in obtaining clean and even transfers during blotting.
Thickness | 1.5 mm |
---|---|
Format | Sheet |
Grade | GB005 |
Material | Cellulose |
For Use With (Application) | Recommended for semidry blotting of proteins |
Cytiva Whatman™ Grade GB003 Blotting Paper
Ensures that no contamination will occur during the transfer steps. Whatman™ Grade GB003 Blotting Paper eliminates sheet to sheet variations with precisely cut membrane sizes.
Thickness | 0.8 mm |
---|---|
Format | Sheet |
Grade | GB003 |
Material | Pure Cellulose |
For Use With (Application) | General purpose paper used as membrane gel support |
Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls
Use this versatile nitrocellulose membrane for excellent binding affinity for small proteins and peptides, as well as nucleic acids. Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
Format | Roll |
---|---|
Length (Metric) | 4 m |
Material | 100% Pure Nitrocellulose |
For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Cytiva Amersham™ Hybond™ PVDF Membranes: Rolls
Ideal for Western blotting applications where stripping and reprobing are necessary. Cytiva Life Sciences™ Amersham™ Hybond™ PVDF Membranes: Rolls are hydrophobic PVDF membranes.
Format | Roll |
---|---|
Dimensions (LxW) | 4 m x 260 mm |
Cytiva Whatman™ Gel Blotting Paper Grade GB003
A thick paper ideal for lysis/denaturation of colony or plaque lifts and Western blots
Grade | GB003 |
---|---|
Material | Cellulose |
For Use With (Application) | Suitable for (lysis/denaturation of colony or plaque lifts and Western blots) |
Thermo Scientific™ Nitrocellulose Membranes, 0.2 μm
Nitrocellulose is a popular binding matrix for western blotting because of its high affinity for proteins and compatibility with a variety of detection methods (western blotting, dot-blot assays, and other protein or nucleic acid methods).
Shipping Condition | Room Temperature |
---|---|
Pore Size | 0.2 μm |
Format | Sheet |
Material | Nitrocellulose |
Thermo Scientific™ Nitrocellulose Membranes, 0.45 μm
Nitrocellulose is a popular binding matrix for western blotting because of its high affinity for proteins and compatibility with a variety of detection methods (western blotting, dot-blot assays, and other protein or nucleic acid methods).
Shipping Condition | Room Temperature |
---|---|
Pore Size | 0.45 μm |
Material | Nitrocellulose |
Invitrogen™ Nitrocellulose/Filter Paper Sandwich, 0.45 μm, 8.3 x 7.3 cm
Ideal for blotting proteins and nucleic acids
Invitrogen™ Power Blotter Select Transfer Stacks, nitrocellulose, regular size
Transfer proteins rapidly and efficiently with these ready-to-use high performance transfer stacks for Invitrogen Power Blotter.
Shipping Condition | Room Temperature |
---|---|
Pore Size | 0.2 μm |
Format | Transfer Stack |
Length (Metric) | 13 cm |
Dimensions (LxW) | Regular, 13 cm x 8.3 cm |
Material | Nitrocellulose |
Width (Metric) | 8.3 cm |
Product Line | Power Blotter |
Thermo Scientific™ Owl™ Blotting Paper
Absorb adequate amounts of buffer for semi-dry electroblotting without the loss of mechanical stability with this high-quality blotting paper.
Flow Rate | 35 mL/min. |
---|---|
Format | Sheet |
For Use With (Equipment) | Owl electroblotting systems |
Packaging Type | Sheets |
Material | 100% Cotton Fiber |
Weight | 183 g/m² |
Product Line | Owl |
Merck Immobilon™-FL PVDF Membranes
Designed specifically for Western blots and protein sequencing. Immobilon™-FL PVDF Transfer Membranes are plain surfaced with 0.45 μm pores and have lower background fluorescence than other membranes. Available in 10 and 20 cm squares and a 3.75 m roll.
Pore Size | 0.45 μm |
---|---|
Color | White |
Material | PVDF |
For Use With (Application) | Fluorescence, Chemifluorescence, Chromogenic, Chemiluminescence |
Thermo Scientific™ Owl™ Transfer Membranes
Perform Western blotting with hydrophobic Thermo Scientific™ Owl™ Transfer Membranes.
Material | Immobilon-P, PVDF |
---|---|
For Use With (Application) | Western blotting |
Product Line | Owl |
Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Sheets
Use for Western blots, dot-blot assays, and other protein or nucleic acid methods. Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Sheets offer excellent sensitivity, resolution, and low background.
Format | Sheet |
---|---|
For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Sartorius™ BF4 Cotton Linter Blotting Paper
High purity cotton linters offer the maximum degree of absorptiveness and cellulose content. With no additives they avoid any interference during the transfer, making them the ideal complement to nitrocellulose blotting membranes.
Cytiva Whatman™ Protran™ Nitrocellulose Blotting Membranes: 0.2μm BA83 Protran
100% pure nitrocellulose to ensure the highest binding capacity possible
Pore Size | 0.2 μm |
---|---|
Binding Capacity | High |
Material | Nitrocellulose |
For Use With (Application) | Suitable for radioactive, colorimetric, fluorescent, and chemiluminescent detection |