Exclusive offers subject to immediate product availability and whilst stocks last. We are unable to guarantee that the goods ordered will still be available at the price indicated on receipt of your order, for an order of several products, the price is valid only on the quantity of product available in stock.
Type | Spring Balance |
---|
Fisherbrand™ Apiezon Grease
Lubricate pumps with this grease. Fisherbrand™ Apiezon Grease is designed for use with Fisherbrand™ rotary vane pumps.
Thermo Scientific™ Elite pH Spear Pocket Testers and Replacement Sensors
Flexible on-the-go pH testing using durable Elite spear pocket testers with replaceable sensors for a variety of applications include food, beverage, agriculture and more!
Temperature Accuracy | Manual input |
---|---|
Temperature Range (English) | 32.0°F to 140.0°F |
Resolution (pH) | 0.01 |
Measurement Modes | pH |
Range (pH) | -1 to 15 |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | 0.0°C to 60.0°C |
Accuracy (pH) | ±0.02 |
Temperature Resolution | 0.1°C, 0.1°F |
Fisherbrand™ Isotemp™ Hotplate Stirrer, Ambient to 300°C, Aluminum
Stirring Range: 50 to 1500 rpm, Shape: Square, Size: 7.25 x 7.25 in., Plug Type: EU and UK
Fisherbrand™ Isotemp™ Hotplate, Ambient to 540°C, Ceramic
Shape: Square, Size: 4.25 x 4.25 in., Plug Type: EU and UK
Fisherbrand™ Multi Function 3D Rotators
For continuous operation, timed operation or different combinations to ensure optimal mixing conditions for any application
Load Bearing Capacity (English) | 2.2 lb. |
---|---|
Load Bearing Capacity (Metric) | 1 kg |
Timer Range |
|
Length (Metric) Platform | 306 mm |
Rotating Angle | 0 to 360° |
Orbit | 23 mm |
Voltage | 100/240 V |
Warranty and Service Offering | 2 Years |
For Use With (Application) | Immune precipitations, Affinity matrix , Trypsinisation, Gel straining and distaining, Antibody staining, Washes, Hybridizations, Southern blots, Western blots |
Temperature Range (Metric) | 5°C to 40°C |
Speed Range | 5 to 100 rpm |
Width (Metric) Platform | 266 mm |
Lovibond™ MD 100 Chlorine Tablet
Lovibond MD 100 Chlorine Tablet, Applications: Testing in the field, laboratory or plant room, Detection Range: 0-6 - 0-10mg/L, Display Type: LCD, Filling Solution Type: Reagent
Thermo Scientific™ Orion™ Dual Star™ pH, ISE, mV, ORP and Temperature Dual Channel Benchtop MeterSureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Accurately monitor pH, ion concentration, mV, ORP and temperature on two channels with our pH/ISE benchtop meter for advanced lab analysis.
Temperature (Metric) Range | -5.0°C to +105.0°C |
---|---|
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
Resolution (pH) | 0.1, 0.01, 0.001 |
Languages | English, Spanish, French, Italian and German |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
Range (pH) | -2.000 to 19.999 |
Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
Channels | 2 |
Accuracy (pH) | ±0.002 |
Power Supply | Universal AC adapter (included) |
Range (ISE) | 0.0001 to 19,900 in ppm, M, mg/L, % or unit-less |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Graphic LCD with Backlight |
Resolution (mV) | 0.1 mV |
Data Points | 1000 with date and time stamp |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Inputs | Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.1°C |
Weight (Metric) | 0.9 kg |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Electrical Requirements | 90 to 260 VAC 50/60 Hz |
Warranty | 3 Year Meter Warranty |
Stability | Smart Stability and Smart Averaging |
Calibration Points (ISE) | 2 to 6 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Isopotential Point | 7.000 pH (adjustable), 1.000 ISE (adjustable) |
AC Adapter | Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003) |
Log Function Type | Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Relative Humidity Range | 5 to 85 %, non-condensing |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | High/low limit alarm |
Dimensions (L x W x H) | 24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.) |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Model | Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter |
Outputs | USB, RS232 |
Range (Relative mV) | ±1999.9 mV |
Calibration Points (pH) | 1 to 6 |
Backlight Option | Yes, adjustable |
Weight (English) | 2 lb. |
Resolution (Temperature) | 0.1°C, 0.1°F |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Range (mV) | ±1999.9 mV |
Range (ORP) | ±1999.9 mV |
Methods | 10 per channel with password protection |
Traceable Clip-On Single-Channel Digital Timer with Calibration
The Clip-On Single-Channel Digital Timer with Calibration is a compact, go-anywhere timer that clips to your lab coat or clip board.
Thermo Scientific™ Orion Star™ A212 Conductivity Benchtop MeterSureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Reliably measure conductivity, TDS, salinity, resistivity and temperature with this conductivity benchtop meter for advanced lab analysis.
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
---|---|
Range (Resistivity) | 2 ohm to 100.0 megohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
Battery Life | 800 hr. |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Graphic LCD with Backlight |
Data Points | 2000 with date and time stamp |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 point temperature offset calibration |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Warranty | 3 Year Meter |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Battery Type | 4 x AA (sold separately) |
Relative Humidity Range | 5 to 85%, non-condensing |
Dimensions (L x W x H) | 24 x 18 x 11 cm (9.5 x 7.1 x 4.3 in.) |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Backlight Option | Yes, selectable |
Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
Methods | 10 per channel with password protection |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
Channels | 1 |
TDS Factor Range | Linear (0.02 to 9.99) |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.1°C |
Weight (Metric) | 0.9 kg |
Calibration Points (Conductivity) | 5 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | Conductivity with calibration editing option and temperature |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP54 |
Model | Orion Star A212 Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter |
Weight (English) | 2 lb. |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5°C to +105°C |
Thermo Scientific™ SuperNuova+™ Hotplate Series
Get reliable performance, dependable safety and simple operation.
Type | Hot Plate |
---|---|
Warranty | 3 Years |
Shape | Square |
Frequency | 50/60 Hz |
Display | LED |
Fisherbrand™ Isotemp™ 4100 H6A Open Heated Acrylic Bath Circulators
Acrylic open heated baths are fitted with bridge plates for placement of the control head
DWK Life Sciences Kimble™ Kontes™ Pestles For Dounce All-Glass Tissue Grinders
All-glass component parts.
For Use With (Equipment) | Dounce tissue grinder |
---|
Fisherbrand™ Traceable™ Excursion-Trac™ Datalogging Thermometer
Traceable™ Excursion-Trac™ Datalogging Thermometer with user-defined time intervals.
Data Memory | 525,600 Readings |
---|---|
Sensor Types | Temperature-Buffered Bottle Sensor |
Calibration | Calibrated |
Includes | Stand, Velcro magnetic strips, wall mount, batteries |
Alarm Types | LED Indicator,Audible,Flashing LCD Segment |
Type | Datalogger |
Display Type | LCD |
Length (English) Cable | 10 ft. (Cable) |
Temperature Range (English) | -58° to +158°F |
Certifications/Compliance | ISO 17025, A2LA, NIST |
Temperature Range (Metric) | -50.00°C to +70.00°C |
Accuracy (Temperature) | ±0.25°C |
Interface | USB |
Temperature Resolution | 0.01° |
Eppendorf™ Centrifuge 5430/5430 RGreener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More About the Greener Choice Program
The unique, cross-over Eppendorf Centrifuge 5430 and 5430 R combine the small footprint of a microcentrifuge with the versatility of a multipurpose centrifuge. Extremely compact, they can accommodate rotors for microplates and 15/50 mL conical tubes as well as Eppendorf tubes and PCR strips.
Timer | 30 sec. to 99:59 hrs., with continuous run function |
---|---|
Voltage | 230 V |
Frequency | 50/60 Hz |
Certifications/Compliance | UL (120 V), CAN/CSA (120 V), CE, RoHS, IVD for certain catalog numbers |
Safety Features | Lid Lock, steel armoured safety chamber, view port for speed validation, lid emergency release, automatic rotor recognition, certified aerosol-tight rotor lids, automatic imbalance recognition |
Display | Large, brightly lit LCD |
*Discount will apply to qualifying orders received by Fisher Scientific between 01/07/2020 and 31/08/2020 subject to availability of the product in stock. Promotion code must be presented at the time of order. Discount applies to the list price in effect at the time the order is received. Promotion cannot be combined with other discounts or promotions. Offer void where prohibited, licensed, or restricted by federal, state, provincial, or local laws or regulation or agency/institutional policy or if the product is no longer available in stock. Other restrictions may apply.