Miscellaneous Immobilized Affinity Ligands
Miscellaneous Immobilized Affinity Ligands
- (3)
- (1)
- (15)
- (3)
- (3)
- (1)
- (2)
- (5)
- (5)
- (1)
- (1)
- (2)
- (8)
- (10)
- (1)
- (1)
Filtered Search Results
Thermo Scientific™ Pierce™ High Capacity Endotoxin Removal Spin Columns, 0.5 mL
Remove endotoxins (lipopolysaccharides or LPS) from samples before mass spectrometry using spin columns of poly(e-lysine) ligand on beaded cellulose.
Stationary Phase | Proprietary Ligand |
---|---|
Type | Spin Column |
Target | Endotoxin Removal |
Content And Storage | Upon receipt store at 4°C. |
Format | Spin Column |
Form | Liquid |
Column Type | Affinity, Cellulose Resin |
Formulation | 8mL-capacity centrifuge columns containing 0.5mL resin |
Capacity (Metric) | Up to 2,000,000 EU/mL |
Product Line | Pierce™ |
Thermo Scientific™ Pierce™ High Capacity Endotoxin Removal Spin Columns, 0.25 mL
Remove endotoxins (lipopolysaccharides or LPS) from samples before mass spectrometry using spin columns of poly(e-lysine) ligand on beaded cellulose.
Thermo Scientific™ Pierce™ Chromogenic Endotoxin Quant Kit
Chromogenic Endotoxin Quant Kits are highly sensitive endpoint assays that measure and detect endotoxin (LPS) in protein, peptide, nucleic acid, or antibody samples using the Amebocyte Lysate Assay from 0.01–1.0 EU/mL. Kits are available in reaction sizes ranging from 30 to 240.
Shipping Condition | Wet Ice |
---|---|
Assay | End-point Chromogenic Assay |
Type | Endotoxin Quantitation Kit |
Target | Endotoxins |
Content And Storage | • Lyophilized amebocyte lysate • E.coli endotoxin standard • Chromogenic substrate • Endotoxin-free water Store at 2–8°C upon receipt. |
Format | Kit |
Assay Sensitivity | 0.01 EU/mL |
Assay Range | 0.01 to 0.1 EU/mL, 0.1 to 1.0 EU/mL |
Product Line | Pierce™ |
Detection Method | Colorimetric |
Thermo Scientific™ Pierce™ High Capacity Endotoxin Removal Resin
Remove endotoxins (lipopolysaccharides or LPS) from samples before mass spectrometry using spin columns of poly(e-lysine) ligand on beaded cellulose.
Stationary Phase | Proprietary Ligand |
---|---|
Type | Resin |
Target | Endotoxin Removal |
Content And Storage | Upon receipt store at 4°C. |
Format | Bottle |
Column Type | Affinity, Proprietary Resin |
Formulation | Proprietary ligand on beaded cellulose slurried in 20% ethanol |
Capacity (Metric) | Up to 2,000,000 EU/mL |
Product Line | Pierce™ |
Thermo Scientific™ Pierce™ High Capacity Endotoxin Removal Spin Columns, 1 mL
Remove endotoxins (lipopolysaccharides or LPS) from samples before mass spectrometry using spin columns of poly(e-lysine) ligand on beaded cellulose.
Stationary Phase | Proprietary Ligand |
---|---|
Type | Spin Column |
Target | Endotoxin Removal |
Content And Storage | Upon receipt store at 4°C. |
Format | Spin Column |
Form | Liquid |
Column Type | Affinity, Cellulose Resin |
Formulation | 22mL-capacity centrifuge columns containing 1mL resin |
Capacity (Metric) | Up to 2,000,000 EU/mL |
Product Line | Pierce™ |
Thermo Scientific™ Pierce™ Boronic Acid Resin
Selectively bind and remove or purify ribonucleotides and small oligonucleotide RNAs using polyacrylamide beads of immobilized m-aminophenyl-boronic acid.
Thermo Scientific™ Pierce™ Iminobiotin Agarose
Agarose beads of immobilized biotin (and iminobiotin) to strongly (or reversibly) bind and remove (or purify) streptavidin or avidin proteins and conjugates from samples.
Invitrogen™ EK-Away™ Resin
Specifically designed for removal of EKMaxor other enterokinase enzymes following cleavage of proteins containing the enterokinase cleavage site
Stationary Phase | Enterokinase |
---|---|
Type | Resin |
Content And Storage | EK-Away™ is provided as a 50% ethanol slurry and should be stored at +4°C. 10X binding and 10X stripping buffers are included. 7.5 ml resin will remove 250 units of enterokinase; 30 ml will remove 1000 units of EKMax™. All reagents are guaranteed stable for 6 months when stored properly. |
Form | Liquid Suspension |
Column Type | Affinity |
Product Line | EK-Away™ |
Thermo Scientific™ Detoxi-Gel™ Endotoxin Removing Gel
Bind and extract endotoxins (lipopolysaccharides or LPS) from antibody or protein samples using bulk resin or columns of immobilized Polymixin B ligand.
Stationary Phase | Polymixin B |
---|---|
Type | Endotoxin Removing Gel |
Target | Endotoxin Removal |
Content And Storage | Store at 4°C. |
Format | Bottle |
Description | Detoxi-Gel Endotoxin Removing Gel |
Column Type | Affinity, Agarose Resin |
Capacity (Metric) | 4000 to 6000 EU Binding per mL Gel |
Product Line | Detoxi-Gel™ |
Thermo Scientific™ Pierce™ D-Galactose Agarose
Bind and affinity-purify lectins, galactosidases and other galactose-binding molecules using this beaded agarose resin with immobilized thio-alpha-D-galactose.
Thermo Scientific™ Detoxi-Gel™ Endotoxin Removing Columns, 1 mL
Bind and extract endotoxins (lipopolysaccharides or LPS) from antibody or protein samples using bulk resin or columns of immobilized Polymixin B ligand.
Thermo Scientific™ Pierce™ p-Aminophenyl Phosphoryl Choline Agarose
Bind and purify C-reactive protein (CRP) using these agarose beads of immobilized p-aminophenyl phosphoryl choline (APC).
Novus Biologicals™ Imiquimod, TLR7 ligand
Applications: Functional, In vitro assay, Ligand Activation
Target | Imiquimod, TLR7 ligand |
---|---|
Content And Storage | Store at 4°C short term. Aliquot and store at -20°C long term. Avoid freeze-thaw cycles. |
Formulation | C14H16N4, HCl |
Concentration | 2.5 mg/mL |
For Use With (Application) | This product is useful for activation of TLR7 and stimulation of TLR7 has been achieved with 5 to 10μL. Use in ligand activation, functional, and in vitro reported in scientific literature (PMID 25957979) |
Species | Human/Mouse |
Target | MALP-2, TLR6 and TLR2 Ligand |
---|---|
Content And Storage | Store at -20C. Avoid freeze-thaw cycles. |
Formulation | C99H167N19O30S |
Concentration | 0.1 mg/mL |
Species | Human/Mouse/Avian |